Brand Name : BIO
Model Number : PM-9000A+
MOQ : 1 unit
Payment Terms : Credit card, Paypal, T/T
Delivery Time : 7 working days at sight of payment
Packaging Details : Carton (38.5*34.5*30.5cm) 5kgs
Supply Ability : 1000 units / month
Screen : 12.1 Inch TFT True color LCD screen
Safty Standard : GB9706.1
ECG waveform : Three-channel
Multi - Parameter : ECG, NIBP, SPO2, TEMP, RESP, Printer (Optional)
Optional : Wall bracket, Mobile bracket, Backpack
Applicant : Bedside Monitoring, ICU/CCU, Emergency Center, Family Monitoring, etc.
conomical Multi - Parameter Patient Monitor With 12.1 Inch TFT True color LCD screen
Features
| 1 | Brand-new high-precision module, with high measurement parameter accuracy, reliable quality and stable performance. | 
| 2 | Rotary shuttle operation mode, Chinese and English logo buttons, easy to learn and use, simple and intuitive operation. | 
| 3 | High-brightness and high-resolution 12.1-inch color TFT LCD display. | 
| 4 | Three-channel ECG waveform, seven-channel simultaneous display of ECG in all leads. | 
| 5 | Multiple display interfaces: single-lead, standard, large font, full-lead, and trend charts coexist. | 
| 6 | The new aluminum alloy internal structure design has good shock resistance and meets the use of mobile environments. | 
| 7 | The new digital blood oxygen technology is adopted to make the measurement of weak perfusion and finger shaking more accurate. | 
| 8 | ST segment automatic detection, arrhythmia analysis, drug concentration drop table analysis. | 
| 9 | The new fully-isolated floating design is resistant to defibrillation and high-frequency electrosurgical interference, and is suitable for use in harsh environments such as operating rooms and wards. | 
| 10 | NIBP dual overvoltage protection temperature drift control and other technologies ensure accurate measurement and protect patient safety. | 
| 11 | Powerful storage capacity, full parameter trend chart data throughout the whole process, ECG waveform storage and playback, and power-down save function. | 
| 12 | Automatic sound and light dual alarm, the upper and lower alarm limits can be set arbitrarily. | 
| 13 | Fanless design, dust-free, low power consumption, and improve the service life of the instrument. | 
| 14 | The body is light and firm, easy to carry, suitable for adults, children and newborns. | 
| 15 | Support wired and wireless networking functions, and support software online upgrades. | 
| 16 | Optional built-in removable rechargeable lithium battery, AC and DC dual purpose, light, energy saving and environmental protection. | 
| 17 | Optional built-in dual-channel thermal array recorder, real-time printing of waveforms and icons. | 
| 18 | It is widely used in bedside monitoring, ICU/CCU, emergency center, family monitoring, etc. in various departments of the hospital. | 
| 19 | Optional wall bracket, mobile bracket, and medical backpack. | 
Standard Configuration
| 1 | PM-9000A+ multi-parameter monitor host | 1 unit | 
| 2 | standard five-lead ECG lead connection cable | 1 set | 
| 3 | standard adult blood pressure cuff | 1 set | 
| 4 | adult blood oxygen probe | 1 set | 
| 5 | temperature probe | 1 set | 
| 6 | power plug cord | 1 set | 
| 7 | ground wire | 1 set | 
| 8 | User's manual | 1 set | 
Optional Configuration
| 1 | Built-in rechargeable lithium battery | 
| 2 | Dual-channel thermal printer | 
| 3 | Monitor cart/bracket/hanger | 
| 4 | Wrapped blood oxygen probe for children or newborns | 
| 5 | Blood pressure cuffs for children or newborns | 
Specification
| 1 | ECG | Lead selection: full lead, Ⅰ, Ⅱ, Ⅲ, aVF, aVR, aVL, V1-6 chest lead display Gain selection: ×1, ×2, ×0.25, ×0.5 four gears Frequency: 0.5Hz—100Hz Common mode signal rejection: greater than 70dB Scanning speed: 12.5mm/s, 25mm/s, 50mm/s three standard files Heart rate accuracy: ±5 beats/minute Calibration signal: 1mV (peak value, accuracy ±3%) ST segment detection: measuring range (-2.0mV---+2.0mV) Use standard: in line with ANSI/AMI EC13-2002 standard Response time: 1S Alarm mode: sound and light alarm Heart rate alarm preset range: (exceed the preset value alarm) The upper limit is adjustable between 1-255 times/minute The lower limit is adjustable between 0-254 times/minute  |  		
| 2 | NIBP |  			 Technology: Oscillographic Method   			Measurement method: reverse measurement data is more accurate   			Unit of measurement: mmHg/Kpa Overvoltage protection: double safety protection One measurement time: less than 45S Pressure range in cuff: 0-250mmHg Blood pressure measurement accuracy: ANSI/AAMI SP10-2002 standard stipulates the average error and standard deviation value Initial inflation of cuff: 180mmHg (120mmHg for children) Cuff subsequent inflation: original systolic blood pressure + 30mmHg Blood pressure measurement range and error: Systolic blood pressure 60 mmHg~250 mmHg Average pressure 45 mmHg~235 mmHg Diastolic blood pressure 40 mmHg~220 mmHg Blood pressure measurement error: ±1.1KPa (±8mmHg) or ±10%, whichever is greater Response time: 1S Alarm mode: sound and light alarm Alarm prediction range and error: (Alarm when exceeding the preset value) Systolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg ~255 mmHg  			Diastolic blood pressure upper limit 1mmHg~255 mmHg Lower limit 0 mmHg~254 mmHg Alarm error: ±1 mmHg Use standard: in line with ANSI/AAMI SP10-2002 standard  |  		
| 3 | SPO2 | Range: 0-100% Accuracy: 1% Resolution: 1% Pulse frequency: 20-250 beats/min Response time: 1S Alarm mode: sound and light alarm Alarm range and error: (Alarm exceeding the preset value) Upper limit 1%~100% Lower limit 0%~99%  |  		
| 4 | TEMP | Technology: Highly sensitive thermistor probe Body temperature measurement range: 20℃-- 45℃ Resolution: 0.1% Body temperature accuracy: ±1℃ Response time: 1S Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 20.1℃-- 45.5℃ The lower limit is adjustable between 20℃ and 45.4℃ Alarm error: ±1℃  |  		
| 5 | RESP | Respiration rate range: 0-60 times/min Accuracy: ±1rpm Response time: 1S Gain options: ×1, ×2, ×4, ×0.5 four gears Alarm mode: sound and light alarm Alarm preset range and error: (Alarm when exceeding the preset value) The upper limit is adjustable between 10-100 times/minute The upper limit is adjustable between 0-99 times/minute Alarm error: ±1rpm  |  		
| 6 | Printer(Optonal) | Specifications: Dual-channel thermal array recorder Printing method: real-time or event trigger recording waveform, text Resolution: Horizontal: 400dpi / Vertical: 800dpi Note: Date (year/month/day)/time (24 hours) Optional wall bracket, mobile bracket, backpack  |  		
| 7 | System | Display: 12.1 inch TFT true color LCD display Safety standard: lec601-1 (International GB9706.1)  |  		

 
| 
                                             | 
                